Official website of Phyto Evolution Pvt Ltd Our official sites

These are the only websites run by Phyto Evolution Pvt Ltd and its partner brands.

  • Phyto Labs phytolabs.in You are here

    The official website of Phyto Evolution Pvt Ltd. Lab-grade tissue culture chemicals, lab setup and consultation services, protocols and our blog.

  • Carnivorous Plants India carnivorousplants.in

    India's exclusive carnivorous plant shop. Nepenthes specimens and bulk lots, shipped pan-India.

  • TC Plants tcplants.in

    Our tissue culture division. Tissue-cultured plantlets, TC grow kits and lab protocols.

  • PhytoStore phytostore.org

    Your own online plant store, live in 24 hours. UPI direct payments and zero commission for plant sellers.

  • Gyrus Tech gyrustech.com

    Operational software for businesses worldwide: farm, production, warehouse, CRM, ERP and e-commerce.

  • Forest Studio Hospitality hospitality.phytolabs.in

    Booking and property management software for hotels, homestays and hostels.

Verify on our Official Sites page →

VPD in a Greenhouse: What It Is and How to Control It

VPD in a Greenhouse: What It Is and How to Control It

Relative humidity alone is a poor guide to how a plant feels, because the same percentage means different things at different temperatures. Vapour pressure deficit (VPD) fixes that by measuring the actual drying power of the air.

What VPD is

VPD is the difference, in kilopascals (kPa), between the amount of water vapour the air could hold at saturation and the amount it holds now. A higher VPD pulls water from the leaf faster; a lower one slows transpiration.

Saturation vapour pressure at temperature T (°C) can be estimated as 0.6108 × e^(17.27 T / (T + 237.3)) kPa. VPD is that value multiplied by (1 − RH/100).

A worked example

At 25 °C, saturation vapour pressure is about 3.17 kPa. At 70 % relative humidity the VPD is 3.17 × 0.30, about 0.95 kPa. Raise the temperature to 30 °C at the same humidity and VPD rises to roughly 1.3 kPa, so the plant transpires harder without any change in the humidity reading.

Typical targets

  • Cuttings, seedlings and freshly hardened plants: low, about 0.4 to 0.8 kPa.
  • Many crops in vegetative growth: about 0.8 to 1.2 kPa.
  • Generative stages: often slightly higher, within the crop’s tolerance.

These are starting points. Each crop and stage has its own optimum, which is why a growth protocol sets VPD per stage.

Why it matters

  • Too low: leaves stay wet, disease pressure rises and calcium moves poorly to new growth.
  • Too high: stomata close to save water, photosynthesis drops and tips can burn.

How to control it

Temperature, humidity and airflow all move VPD. Vents, fans and screens lower temperature; fogging and misting raise humidity while also cooling; dehumidification and heating lower humidity at night. A controller that reads temperature and humidity together can act on VPD directly instead of on two separate set-points.

Our greenhouse design and control service builds this logic into the climate controllers and the control software. Related reading: PPFD and DLI and greenhouse irrigation control.